Menu

Temadur 90 THL-209 (small metallic)

Product available
Temadur 90 THL-209 (small metallic)
1 hrn
Sku: -
Product available
Select tinting/texture
Selected tinting/texture

Product info

Two-component, high-gloss polyurethane paint with a hardener based on aliphatic isocyanate for painting vehicles and traction equipment, external surfaces of tanks, steel frames, etc. Steel structures, machines.

Courier
1 - 2 days
The cost is calculated after ordering

Delivery on weekends and later times is negotiable. The cost of delivery should be specified. Delivery of tinted paint is by prepayment only.

Local pickup from store
Kyiv, Ivana Vyhovskoho Street, 9A
Free

Pickup is possible on Mon-Fri, from 9 AM to 6 PM

reCaptcha: Error reCaptcha: Timeout exceed
Rate this product: Your mark:
TYPE Two-component, high-gloss polyurethane paint with a hardener based on aliphatic isocyanate. FIELD OF APPLICATION Recommended as a glossy topcoat in epoxy systems for painting surfaces exposed to weathering and / or chemicals. objects of application For painting of vehicles and traction equipment, external surfaces of tanks, steel frameworks, etc. Steel structures, machines and equipment. TECHNICAL DATA Features It has an excellent atmosphere and durability.
Forms a stable, easy-to-clean, non-grinding coating, retains color and shine well.
When finishing internal wooden surfaces, read in detail the "Instructions for use Temadur 90 with hardener 008 7596".
Hardener 008 7594 is recommended for use in warm humid conditions. color Colors according to color catalogs RAL, NCS, SSG, BS, Monicolor Nova and Symphony. color catalogs Colored according to the TEMASPEED system. degree of brilliance glossy cost The recommended film thickness is dry 40 μm. The recommended film thickness is 75 μm wet. Theroethical expense - 13,7 sq.m / l. The practical cost depends on the conditions and method of application, as well as the shape and roughness of the painted object. Diluent 1048, 1067 and 1061 mixing ratio Base - 5 parts by volume, 115-series
Hardener - 1 part by volume, code 008 7590 or 008 7594 method of application Airless or traditional spray or brush. In order to obtain a smooth, non-porous surface, apply the first thin layer, allow the solvent to evaporate for 5-30 minutes, and then apply a finishing layer.
Depending on the temperature of the components (base, hardener and solvent), the paint can be diluted by 10-22% to a working viscosity of 20-25 seconds. DIN 4. Diameter of a nozzle of an airless spray 0.011 "-0.013"; pressure 120-160 bar; the spray angle is selected depending on the shape of the painted structure. When applying the paint, dilute the paint depending on the conditions when painting. The viability of the mixture (+23 ° C) 4 years drying time The thickness of the dry film is 40 μm + 5 ° С From dust, after that - 45 min. The thickness of the dry film is 40 μm + 10ºC from dust, after that - 30 minutes. The thickness of the dry film is 40 μm + 23ºC From dust, after that - 20 minutes. The thickness of the dry film is 40 μm + 35ºC From dust, after that - 10 minutes. The thickness of the dry film is 40 μm + 5 ° С. The thickness of the dry film is 40 μm + 10ºC On sticking, then - 8 hours The thickness of the dry film is 40 μm + 23ºC On sticking, then - 4 hours The thickness of the dry film is 40 μm + 35ºC. Interlayer exposure - no restrictions Drying time and interlayer exposure depend on the film thickness, temperature, relative humidity and ventilation. Dry residue 55 ± 2% by volume (ISO 3233);
68 ± 2% by weight. density 1.2 ± 0.1 kg / liter (ready-to-use mixture). code Base - 115 7221 (TAL base), 115 7223 (TCL base), 115 7230 (THL base), 115 7240 (TML base), hardener - 008 7590. INSTRUCTIONS FOR USE Processing conditions All surfaces must be dry. When applying and curing the paint, the temperature of the painted air and paint should not fall below + 5 ° C. The relative humidity should not exceed 80%. The temperature of the steel surface must be at least 3 ºC above the dew point of the air. preliminary training Primed surfaces: Remove oils, lubricants, salts and mechanical contaminants from the surface by appropriate methods. Eliminate defects in the primer. Warning! It is necessary to remember about interlayer endurance of a first coat. (ISO 12944-4) priming Temacout GPL-S Primer, Temacout GF Primer, Temacout HB Primer, Temacout PM Primer, Temacout GPL-S MIO, Temacout PM 40, Temacout SPA, Temabond, Temadur 20, Temadur Primer, Temaprimel GF. dilution Solvent forty-eight or 1067. Solvent 1061 (fast) is also suitable for traditional spraying. integumentary coloring Temadur and Tematein. color Airless or traditional spray or brush. In order to obtain a smooth, non-porous surface, apply the first thin layer, allow the solvent to evaporate for 5-30 minutes, and then apply a finishing layer.
Depending on the temperature of the components (base, hardener and solvent), the paint can be diluted by 10-22% to a working viscosity of 20-25 seconds. DIN 4. Diameter of a nozzle of an airless spray 0.011 "-0.013"; pressure 120-160 bar; the spray angle is selected depending on the shape of the painted structure. When applying the paint, dilute the paint depending on the conditions when painting. mixing of components Stir the paint and hardener in separate containers before use. Then mix the paint thoroughly with the hardener in the correct ratio. It is recommended to use a rotary-elevator mixer for mixing. cleaning tools Solvents 1048, 1 067 or 1061.
Product details
Thinner:

Растворитель;

Gloss degree:

Глянцевый;

Is tinting available:

Yes;

Компонентный состав:

2-компонентные;

Тип помещения:

Для внешних работ;

Тип:

Краска;

Тип поверхности:

Металл;

Manufacturer: Tikkurila Coatings

0 Ratings

0 Overall rating

0 out of 0 (0%)
Customers recommended this product

5
0
4
0
3
0
2
0
1
0
Top