Menu

Temadur 20 TCL

Product available
Temadur 20 TCL
1 hrn
Sku: -
Product available
Select tinting/texture
Selected tinting/texture

Product info

Two-component, semi-matt polyurethane paint containing anti-corrosion pigments, with a hardener based on aliphatic isocyanate for painting vehicles and traction equipment, external surfaces of tanks, steel frames and

Courier
1 - 2 days
The cost is calculated after ordering

Delivery on weekends and later times is negotiable. The cost of delivery should be specified. Delivery of tinted paint is by prepayment only.

Local pickup from store
Kyiv, Ivana Vyhovskoho Street, 9A
Free

Pickup is possible on Mon-Fri, from 9 AM to 6 PM

reCaptcha: Error reCaptcha: Timeout exceed
Rate this product: Your mark:
TYPE Two-component, semi-matt polyurethane paint containing anti-corrosion pigments, with a hardener based on aliphatic isocyanate. FIELD OF APPLICATION Recommended as surfaces in epoxy systems or semi-matt finishes in polyurethane systems for painting surfaces exposed to weathering and / or chemicals. Due to anti-corrosion pigments, it is also used as an independent single-layer coating for steel, galvanized and aluminum surfaces. objects of application For painting of vehicles and traction equipment, external surfaces of tanks, steel frameworks, etc. Steel structures, machines and equipment. TECHNICAL DATA Features It has an excellent atmosphere and durability.
The material is certified by MED (Marine Equipment Directive) № VTT-C-11167-15-14, ie it can be used for painting surfaces inside ships. color Colors according to color catalogs RAL, NCS, SSG, BS, Monicolor Nova and Symphony. color catalogs Colored according to the TEMASPEED system. degree of brilliance semi-matte cost Recommended film thickness dry - 40 microns. Theoretical consumption - 14.2 sq.m / l. dry - 100 microns. Theoretical consumption - 5.7 sq.m / l. wet - 70 microns. Theoretical consumption - 14.2 sq.m / l. wet - 175 microns. Theoretical consumption - 5.7 sq.m / l. The practical cost depends on the conditions and method of application, as well as the shape and roughness of the painted object. Solvent - 1048, one thousand sixty-seven and +1061 mixing ratio Basis - 5 parts by volume, 114-series
Hardener - 1 part by volume, code 008 7590 method of application Airless or traditional spray or brush. Depending on the temperature of the components (paint, hardener and solvent) and the desired working viscosity, the paint is diluted by 0-20%. Diameter of a nozzle of an airless spray 0,011 "-0,015"; pressure 120-160 bar. The spray angle is selected depending on the shape of the painted structure. When applying the paint, dilute the paint depending on the conditions when painting. The viability of the mixture (+23 ° C) 4. hours drying time Dry film thickness 50 μm + 5 ° С - From dust, after 45 min. Dry film thickness 50 μm + 10ºC - From dust, after 30 minutes. Dry film thickness 50 μm + 23ºC - From dust, after 15 minutes. Dry film thickness 50 μm + 35ºC - From dust, after 10 minutes. The thickness of the dry film is 50 μm + 5 ° C - On sticking, after 8 hours The thickness of the dry film is 50 μm + 10ºC - On sticking, after 6 hours The thickness of the dry film is 50 μm + 23ºC - On sticking, after 4 hours. The thickness of the dry film is 50 μm + 35ºC - On sticking, after 2 hours. Interlayer exposure - no restrictions Drying time and interlayer exposure depend on the film thickness, temperature, relative humidity and ventilation. Dry residue 57 ± 2% by volume (ISO 3233);
70 ± 2% by weight. density 1.3 ± 0.1 kg / liter (ready to use mixture). code Base - 114 7223 (TCL base), 114 7226 (TVL base), hardener - 008 7590. Attention! Check the correctness of the code with Tikkurila specialists. INSTRUCTIONS FOR USE Processing conditions All surfaces must be dry. When applying and curing the paint, the temperature of the ambient air to be painted and the paint should not fall below +5 ºC. Relative humidity should not exceed 80%. The temperature of the steel surface must be at least 3 ºC above the dew point of the air. preliminary training Remove oils, lubricants, salts and mechanical contaminants from the surface by an appropriate method (ISO 12944-4).

Steel surfaces: Treatment by abrasive blasting to the degree of diligence Sa2½. (ISO 8501-1). If abrasive blasting is excluded, it is recommended to carry out phosphating of a cold-rolled steel surface for improvement of adhesion.

Galvanized surfaces: Easy abrasive blasting with the use of a mineral abrasive, such as quartz sand, to the degree of thoroughness (SaS, SFS 5873). If light abrasive blasting is excluded, the surface should be sanded by hand or rinsed with Pansaripes material.

It is recommended to apply a thin layer of 25-30% diluted paint on the hot-dip galvanized surface before applying the primer.

Aluminum surfaces: Easy abrasive jet cleaning with the use of non-metallic abrasive to the degree of thoroughness (SaS, SFS 5873). If light abrasive blasting is excluded, the surface should be sanded by hand or washed with Maalipes material.

Stainless steel: Grinding or light abrasive blasting with a mineral abrasive.
Product details
Thinner:

Растворитель;

Gloss degree:

Полуматовый;

Resistance to washing:

Очень стойкая;

Is tinting available:

Yes;

Компонентный состав:

2-компонентные;

Тип помещения:

Для внутренних работ;
Для внешних работ;

Тип:

Краска;

Тип поверхности:

Металл;

Manufacturer: Tikkurila Coatings

0 Ratings

0 Overall rating

0 out of 0 (0%)
Customers recommended this product

5
0
4
0
3
0
2
0
1
0

Similar items in category Крыша, Металлоконструкции

Yuki matte paint for the base
Tikkurila

Yuki matte paint for the base

280 hrn
Prof. tinting
Pansarimaali
Tikkurila

Pansarimaali

382 hrn
Prof. tinting
-17%
Miranol
Tikkurila

Miranol

377 hrn
454 hrn
-5%
Oteks Aqua
Tikkurila

Oteks Aqua

459 hrn
484 hrn
-14%
Vinha
Tikkurila

Vinha

340 hrn
394 hrn
Socks
Kolorit

Socks

434 hrn
Prof. tinting
Standart A
Kolorit

Standart A

0 hrn
Prof. tinting
Top